ADVANCE-FORSEE study protocol: Advanced video monitoring for early signalling of adverse events and optimal discharge planning in cardiac surgery patients
Figures
Abstract
Background
Postoperative complications remain common after cardiac surgery, while manual nurse-led vital signs monitoring on post-cardiac surgery wards may delay their detection. Early recognition of clinical deterioration leading to complications is therefore essential to reduce post-surgery morbidity, and mortality. Conversely, personalised early discharge for patients with a fast and uneventful recovery may prevent unnecessarily delayed discharge and thereby free up hospital capacity.
Objectives
This study protocol describes the planned evaluation of the feasibility and acceptability of continuous video-based monitoring for early detection of postoperative deterioration as well as identification of uneventful recovery in cardiac surgery patients.
Methods
This single-centre prospective observational study will include cardiac surgery patients admitted to the cardiothoracic surgery ward, with a target sample size of 300 patients. Video recordings will be made during postoperative ward stay and processed retrospectively to extract heart rate, arrhythmias, and respiration rate as well as contextual parameters (e.g., posture, movement and facial cues). These video-derived features will be used to train and evaluate machine-learning models for early detection of postoperative deterioration and assessment of discharge readiness.
Results
Patient enrolment is scheduled to start in November 2026 and is expected to be completed by November 2028. The first deterioration detection and discharge readiness models are expected by December 2028.
Conclusions
The ADVANCE-FORSEE study was initiated to test the hypothesis that, by using video-based monitoring, we will be able to (1) mitigate the number and impact of postoperative adverse events and (2) identify patients with an uneventful recovery in an early stage. These insights may contribute to the development of tailored and individualised postoperative care pathways.
Citation: Delbressine JJ, van Steenbergen GJ, Cramer IC, van Esch RJ, Verstappen CC, van der Hoorn JW, et al. (2026) ADVANCE-FORSEE study protocol: Advanced video monitoring for early signalling of adverse events and optimal discharge planning in cardiac surgery patients. PLoS One 21(11): e0362169. https://doi.org/10.1371/journal.pone.0362169
Editor: Katrien G. Janin, PLOS: Public Library of Science, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
Received: October 15, 2026; Accepted: October 20, 2026; Published: November 24, 2026
Copyright: © 2026 Delbressine et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: No datasets were generated or analysed as part of this study protocol. The raw video data that will be generated and analysed during the ADVANCE-FORSEE study will not be made publicly available due to their highly sensitive and identifiable nature as well as the restrictions imposed by the ethics protocol to safeguard the privacy of patients involved. Researchers may submit a request for controlled access to the underlying minimal dataset through the AI expertise center of the Catharina Hospital at ai@catharinaziekenhuis.nl. Access requests will be assessed in accordance with applicable ethical, legal, privacy and institutional requirements. If approved, the data may be analysed within the secure AI platform on the premises of Catharina Hospital at cost, with no markup applied. The raw video data cannot be transferred outside this secure environment.
Funding: This work was supported by The Netherlands Organisation for Health Research and Development (ZonMW, grant number 11320102410045, received by Jesse J. Delbressine, Iris C. Cramer, Rik J.C. van Esch, Cindy C.A.G. Verstappen, Mohamed A. Soliman-Hamad, and Lukas R.C. Dekker). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: The authors have declared that no competing interests exist.
Introduction
In 2024, almost 10,000 cardiac surgical procedures were performed in the Netherlands alone. This number may increase due to an ageing population, sedentary lifestyles and improvements in diagnostic techniques [1]. Despite a decline in one-year postoperative mortality from 3.4% in 2014 to 2.3% in 2024, further improvement in postoperative outcomes remain warranted [1].
Adverse events are often preceded by relevant changes and trends in vital signs, offering a window of opportunity for early detection of clinical deterioration [2–4]. However, current postoperative monitoring on hospital wards primarily relies on manual intermittent nurse-led vital sign assessments, which may not adequately capture clinically relevant changes over time and contribute to nursing workload [5,6]. Consequently, deterioration and complications occurring between assessments may remain undetected until the next scheduled assessment multiple hours later.
Although continuous wireless monitoring can facilitate more frequent detection of vital sign abnormalities, existing systems generally rely on patient-worn sensors that may cause discomfort, skin irritation or restrictions in mobility [7–10]. Contactless video-based monitoring (VBM) may overcome some of these limitations by enabling unobtrusive monitoring of vital signs and contextual parameters [11–14]. In previous studies we validated VBM for continuous monitoring of heart rate and respiratory rate in the intensive care unit (ICU) and demonstrated its ability to detect cardiac arrhythmias [15,16]. However, the feasibility and acceptability of prolonged continuous VBM under real-world conditions on cardiac surgical wards remains unknown.
We hypothesise that continuous VBM technology is able to identify trends in vital signs and contextual data of cardiac surgery patients that may enable early detection of postoperative deterioration and early recognition of patients likely to follow an uneventful recovery. Such information could ultimately facilitate timely clinical interventions, reduce the impact of complications and support the development of personalised postoperative care pathways. As a first step towards evaluating this potential clinical value, the ADVANCE-FORSEE study aims to determine the feasibility and acceptability of continuous video-based monitoring under real-world conditions.
Methods
Study design
This study is a prospective observational study conducted at the CZE in the Netherlands. The study was reviewed and approved by the medical ethical committee MEC-U in Nieuwegein, the Netherlands (file number: NL-011749). The study is registered in clinicaltrials.gov with registry number: NCT07486258.
Study population and inclusion
Patient enrolment and data collection are scheduled to start in November 2026 and are expected to be completed in November 2028. The first deterioration detection and discharge readiness models are expected by December 2028.
Study procedures
Following surgery, patients will be admitted to the ICU and subsequently transferred back to the CTS ward, where VBM will be initiated in one of the six dedicated rooms equipped with a camera set-up. To enrich the study population for postoperative complications while ensuring a transparent and reproducible allocation procedure, available VBM-equipped rooms will be allocated to eligible patients in descending order of EuroSCORE II at the time of allocation. If the number of eligible patients exceeds the number of available VBM-equipped rooms, the remaining patients will be assigned to non-VBM equipped rooms on the CTS ward.. The camera unit is mounted above the television in each room, as show in Fig 1a.
Video-data will be captured using a multimodal camera system consisting of a red-green-blue (RGB) camera (U3-3860CP-C-HQ Rev.2.2, IDS GmbH), a near-infrared (NIR) camera (U3-3860CP-M-GL Rev.2.2, IDS GmbH) a thermal camera (Flir Lepton 3.5) and a NIR light source (Raytec VAR2 i4-1). The RGB and NIR cameras will operate at 32 frames per second, using varifocal 8–46 mm focal length lenses (Computar H6Z0812) with fully open apertures. Further technical specification and camera settings have been described in a previous study by our research group [15]. Representative examples of RGB and NIR video recordings are shown in Fig 2. To protect privacy, a physical cover is installed in front of the cameras that can be closed at any time by either the patient, visitors, or healthcare staff by pulling a cord located beneath the television (Fig 1b). During the recording period, no real-time analysis will be performed. Video recordings will not be made available to physicians or nurses and clinical decisions will not be based on the recordings. All analyses will be conducted retrospectively. Data storage, access procedures and processing infrastructure are described in the video-derived data handling and analysis chapter. Continuous reference measurements will be obtained using the Philips IntelliVue MX40, a wearable patient monitor used for clinical monitoring. The recorded vital signs will be wirelessly transmitted to the CZE data warehouse.
VBM will not interfere with or affect the standard care pathway on the CTS ward during this study. During the postoperative CTS ward stay, patients will continue to receive routine clinical care, including intermittent measurements and assessment of vital signs by nursing staff. VBM will be discontinued if the patient is transferred to another ward, requests discontinuation or if the treating physician or nurse considers continuation no longer appropriate. Upon discharge, patients will be asked to complete a questionnaire regarding their experience with and preferences for the VBM system and a subset of patients will additionally be invited to participate in interviews.
Healthcare professionals working on the CTS ward will also be asked to complete questionnaires at selected time points during the study, with the timing determined based on study progress and their exposure to the VBM system. A subset of the professionals will be invited to participate in focus groups regarding their experiences with the VBM system, including its perceived added value, trustworthiness, impact on workflow and potential integration into clinical practice.
Thirty-day post-discharge outcomes will be collected via the Netherlands Heart Registry (NHR) to evaluate early postoperative outcomes. Table 1 illustrates the patient journey before and during study participation.
Outcome measures
Primary outcomes
The primary outcomes are the performance of the algorithms for detecting postoperative deterioration and identifying uneventful recovery during hospital admission.
Postoperative deterioration is defined as worsening of the postoperative clinical status, reflected by deviations in vital signs relative to an individual reference period, leading to a complication as defined in S1 Table. All complications will be diagnosed by the treating physician and defined according to NHR standards or relevant medical scientific committee guidance [17]. Deterioration is expected to require additional unplanned care or intervention. A data monitoring board will perform a blinded appraisal of the annotated events to confirm the occurrence of postoperative deterioration and, where possible, verify the estimated time of onset.
Uneventful recovery is defined as a postoperative trajectory without predefined complications, reflected by the absence of abnormal trends in measured vital signs and without unplanned additional care or intervention.
Secondary outcomes
Secondary outcomes are: (1) detection of the most common and impactful complications after cardiac surgery, as listed in S1 Table; (2) the predictive value of each extracted camera-based parameter for detecting postoperative deteriorations, complications and uneventful recovery; (3) the time interval between algorithm-based detection and clinical confirmation by the treating physician; (4) the predictive value of video-derived parameters during hospital admission for deterioration and complications occurring within 30 days after discharge using NHR data; (5) the robustness of the VBM system across different skin types and under varying real-world conditions such as differences in lighting, occlusion, posture and movement and (6) the acceptability of the VBM system among healthcare staff, patients and family members encompassing privacy, comfort, perceived feeling of safety, ease of use, trust in the system, perceived ability to mobilise freely and preferences regarding system functionalities and implementation.
Process measures
Video-derived data handling and analysis
Data storage and access
All video recordings will be stored in a secured database within the CZE and will be evaluated retrospectively. Access to the raw video database will be restricted to the coordinating investigators and all processing will take place within the hospital’s secure data platform. The resulting processed data are not traceable to individual patients.
Signal extraction and parameter quantification
To estimate a patient’s clinical status, physiological parameters, including heart rate, heart rhythm and respiratory rate, as well as contextual parameters, including posture, movement and facial cues, will first be derived from the video recordings. To facilitate robust longitudinal analysis of these parameters while limiting storage demands, raw video data will be converted into analysable datapoints using a structured signal extraction and processing pipeline, schematically presented in Fig 3.
RGB red, green and blue; NIR near-infrared, ROI region of interest, rPPG remote photoplethysmography.
This process will start with the acquisition and preprocessing of the multimodal video streams, including quality screening based on image brightness and patient presence. Segments without relevant information (i.e., no patient detected) will be excluded from further analysis. Regions of interests (ROIs) will be detected using an opensource face detector, Tiny Faces [18], and tracked across frames using a kernelized correlation filter. The specific detector may be updated during the study to improve technical performance, any changes will be documented and reported.
Heart rate and heart rhythm will be estimated using the plane-orthogonal-to-skin (POS) algorithm as described by Wang et al. [19,20]. POS is a remote photoplethysmography (rPPG) method which extracts a pulse waveform from subtle colour variation in a skin ROI over time. By projecting the extracted signals onto a plane orthogonal to the skin, POS aims to suppress motion- and illumination induced distortions in the pulse signal. Respiratory rate will be estimated using the optical-flow based motion method, OF-M1D described by Wang et al. [21], which derives a respiratory waveform from respiration induced chest motion within the corresponding ROI. Fig 4 provides a detailed illustration of the signal extraction and processing steps used to derive heart rate and respiratory rate from the video recordings.
(A): Multimodal video acquisition and identification of the facial ROI (red box) and chest ROI (yellow box).(B1): Light incident on the skin is partly absorbed and partly reflected. Within the facial ROI, pulsatile changes in blood volume produce subtle variations in the reflected light intensity, which are recorded by the cameras.(B2): Respiratory chest movement is measured by tracking the displacement of pixels within the chest ROI over consecutive frames.(C1): Raw RGB intensity signals extracted from the facial ROI.(C2): Raw chest-motion signal extracted from the chest ROI.(D1): rPPG waveform derived by processing the raw RGB intensity signals.(D2): Respiratory waveform derived by processing the raw chest-motion signal.(E1): Heart rate estimated from the periodicity of the rPPG waveform using time- or frequency domain analysis.(E2): Respiratory rate estimated from the periodicity of the respiratory waveform using time- or frequency domain analysis.
As these video-derived parameters may be influenced by external factors such as lighting, occlusion by blankets or other objects, patient posture and movement, signal quality will systematically be assessed [22]. For each analysis window, time- and frequency domain signal characteristics will be evaluated to identify low-quality or unreliable measurements. For example, noise or motion artefacts may result in multiple competing peaks in the frequency spectrum, increasing the risk of selecting an incorrect frequency and thereby over- or underestimating the derived parameter. Previous work has shown that signal quality indices and frequency domain features can support the distinction between reliable and unreliable rPPG segments [22,23]. These studies will guide the selection of signal quality metrics to identify low-quality measurements and inform their handling, with additional metrics incorporated where appropriate.
Patient posture and movement will be detected and quantified using pose estimation and optical flow methods to classify in-bed body posture and track motion within specific ROIs [24,25]. Following the approach described by Peng et al. [26], detected motion will be further categorised into gross motion and fine motion to distinguish larger body movements from subtle physiological motion. The influence of these motion features on the accuracy of the video-derived heart rate, heart rhythm and respiratory rate will subsequently be assessed. In addition, facial cues associated acute illness will be quantified using machine learning models either through a newly developed model trained on annotated video data or, depending on performance and feasibility, an established pre-trained model [13,27].
Model development and performance analysis
Video-derived physiological signals and contextual parameters will serve as input features for machine learning models aimed to retrospectively estimate the clinical status, including postoperative deterioration and discharge readiness. Temporal changes in the derived parameters within a monitoring window will be evaluated relative to an individual reference period. The estimated time of occurrence of postoperative deterioration and complications will be used as labels for model training, validation and testing.
Initial model development will focus on extreme gradient boosting (XGBoost), a machine-learning method based on sequentially constructed decision trees [28]. XGBoost was selected because it is well suitable for relatively small and structured datasets, can model non-linear associations between physiological and contextual parameters and clinical status, and provides measures of feature importance that may support model interpretation. Its applicability to structured clinical data has previously been demonstrated for outcome prediction after cardiac surgery [29].
If XGBoost does not sufficiently capture temporal patterns preceding postoperative deterioration or characterising uneventful recovery, recurrent neural networks approaches may be explored. In particular, long short-term memory (LSTM) models may be considered, as these models are designed to analyse sequential data by efficiently discarding and retaining information from previous time points [30]. LSTM models have previously been applied to longitudinal vital sign data to identify deteriorating patients [31].
The data monitoring board approved annotations will subsequently be used as the reference standard to evaluate algorithm performance for detecting postoperative deterioration and uneventful recovery using receiver operating characteristic (ROC) analysis, including the area under the curve (AUC) and corresponding 95% confidence intervals. Sensitivity, specificity, positive and negative predictive values will also be reported. The timing of successful early detection will be evaluated using lead time, defined as the time interval between algorithm-based detection and clinical confirmation of postoperative deterioration or complications. Lead time will be reported as a continuous measure and categorised into predefined relevant intervals: < 30 minutes, 30 minutes to <1hour, 1 to < 4 hours and ≥4 hours before clinical confirmation. For discharge readiness the timing of model-estimated readiness for discharge will be compared with the standard discharge protocols and actual discharge data. Model-based discharge readiness will be considered clinically relevant if the model identifies patients as potentially ready for discharge earlier than routine care provided that 30-day post-discharge follow-up data, including NHR data, confirm an uneventful recovery without postoperative complications.
Statistical considerations
Descriptive, comparative and acceptability analyses
Baseline characteristics of the study population will be reported as counts and percentages for categorical variables and as mean ± standard deviation or median with interquartile range for normally and non-normally distributed continuous variables, respectively. Patients with and without postoperative complications will be compared using Fisher’s exact test for categorical variables data, the independent sample T-test for normally distributed continuous data and the Mann-Whitney U test for non-normally distributed continuous data. A p-value < 0.05 is considered statistically significant. Questionnaire data will be analysed using descriptive statistics while qualitative data from the focus groups will be analysed using thematic analysis. All statistical analysis will be performed using SPSS or R-studio.
Data completeness
The extent, pattern and underlying causes of missing data will be evaluated. Missing data resulting from closure of the privacy hatch or absence of the patient from bed will be treated as informative outcomes reflecting data coverage, mobilisation and privacy-related aspects, rather than as missingness. Missing data caused by technical issues such as corrupted data or storage failures, will be considered true missingness. The handling of such missing data will depend on the extent and mechanism of missingness and will be reported transparently.
Sample size calculation
The sample size required for the development of a machine learning model is estimated using equation (1) [32]:
(1)where represents the required number of participants needed, the number of events per variable, the number of prediction variables included in the model and the prevalence of clinical deterioration in the study population. For prognostic modelling it is aimed to have ≥ 10 events per prediction variable, therefore is set at 10. According to Ball et al. the prevalence of clinical deterioration is estimated to be around 10% [33]. Therefore, a model including two prediction variables (heart rate and respiratory rate) would require at least 200 patients. The target study sample size was increased to 300 patients to allow for the possible inclusion of additional prediction variables, including other vital signs such as oxygen saturation and blood pressure as well as contextual parameters.
Discussion
Principal aim & rationale
The ADVANCE-FORSEE study will evaluate the feasibility of continuous video-based monitoring for the early detection of postoperative deterioration and identification of uneventful recovery in cardiac surgery patients. By generating prospective evidence on the association between video-derived vital signs and contextual parameters on the one hand, and clinically relevant deterioration and recovery trajectories on the other, this study may support earlier recognition and timely management of postoperative complications. It may also inform more personalised discharge planning and future integration of VBM into clinical workflows. Importantly, video footage will be recorded for research purposes only and will not be used to guide real-time clinical decision-making. The findings will primarily inform feasibility, performance and implementation requirements of VBM in preparation for a future randomised controlled trial.
Although video-based vital sign monitoring has been extensively studied among healthy volunteers and under controlled settings, clinical evidence remains limited to short recording periods and predominantly non-postoperative population [11,12,34–37]. Building on our earlier work demonstrating accurate prolonged monitoring in the ICU and rhythm discrimination [15,16], ADVANCE-FORSEE is novel in evaluating continuous VBM in postoperative cardiac surgery patients throughout their stay at the CTS ward. The study will focus on deterioration detection, characterization of uneventful recovery trajectories and the requirements for future integration into clinical workflows.
VBM may also offer practical benefits within healthcare. An internal analysis at CZE, based on 75 observations, determined that the median duration of a bedside vital sign assessment was 71 seconds. For a ward with 64 patients undergoing three assessments per day, this corresponds to nearly 4 hours of nursing time per day. Moreover, implementation of continuous wearable monitoring on a surgical ward reduced nurse-led vital sign assessments by 62.7% [6]. If part of these routine assessments could eventually be supported or replaced by automated monitoring, nursing time could be redirected towards more personalised care and mobilisation support after surgery. Unlike wearable monitoring systems, VBM does not require patient-worn sensors and may therefore reduce skin-related discomfort, preserve patients’ ability to mobilise freely and reduce reliance on disposable sensor materials [10]. VBM may additionally provide contextual information that is not available from conventional vital sign monitoring alone [13].
Algorithm specific considerations
For VBM to generate outputs that may meaningfully support clinical decision-making, the reliability and interpretability of the derived signals must first be established. Signal completeness and measurement quality may be affected by the quality of the input video data, which depends on factors such as movement, occlusion, illumination, skin tone and other real-world variations. These factors were anticipated during study design and are considered inherent to real-world VBM on a general ward rather than threats to overall study feasibility. Events such as temporary absence from bed, presence of visitors or closure of the privacy hatch will be quantified as part of the assessment of feasibility, robustness and data coverage. To minimise avoidable interruptions, patients and visitors are informed about the VBM set-up within the room. Failures, missing data, low-quality measurements and corresponding mitigation strategies will be described in future publications.
Possible future adoptions
This project may lay the foundation for future non-invasive and unobtrusive monitoring strategies that allow patients to mobilise freely while remaining continuously monitored. By reducing the reliance on routine bedside vital sign assessments, the envisioned technology could help alleviate nursing workload and create more time for personalised care and mobilisation support. In addition, continuous VBM may reduce the risk that clinically relevant changes occurring between nurse-led vital sign assessments remain unnoticed.
Beyond the potential impact on the nursing ward, insights gained from this study may pave the way for broader use of VBM in home settings and during follow-up video consultations, where vital signs could potentially be assessed remotely. Furthermore, the continuous collection of physiological and contextual data using VBM may support the future development of digital twin applications.
Although the system outputs will not be used to guide clinical decision in the current study, nursing staff and physicians will be actively involved as intended end-users to identify and prioritise user requirements for future integration in their workflow. This will include questionnaires, workgroup sessions and one-on-one interviews to explore their preferences regarding the most useful outputs, the optimal presentation of information and the appropriate communication of poor-quality or unavailable data.
Privacy safeguards
For VBM to be acceptable in routine clinical care, privacy concerns need to be explicitly addressed. Prior research has shown that a perceived sense of control is an important condition for acceptance of VBM and previous work from our research group reported a participation rate of 95% among eligible patients, with no privacy concerns identified in survey responses [38,39]. In the current study, privacy safeguards include a physical hatch allowing, patients, visitors and healthcare staff to suspend video recording at any time as well as clear information on the system’s purpose and basic working principle. Patient perspectives will be captured through questionnaires and interviews, supplemented by feedback from individuals with lived experience affiliated with the Dutch Heart Foundation.
Limitations
This study has several limitations. First, the incidence of major postoperative complication has decreased over time and the prevalence of some individual complication is relatively low (<10%) [40,41]. Consequently, the number of observed events may be limited which may restrict the evaluation of the predictive models for deterioration detection.
Second, the study design may be prone to selection bias. Since patients with a higher estimated probability of developing complications are preferentially allocated to VBM-equipped rooms, the study sample may be less representative of the overall cardiac surgery population, thereby limiting generalisability of the findings. Additional selection bias may be introduced by routine room allocation as certain patient groups may be assigned to single-occupancy rooms or to specific areas of the CTS ward, for example due to an increased risk of arrhythmia or delirium.
Third, VBM with the current camera system is limited to periods during which the patient remains within the camera’s restricted field of view. When patients are out of bed, for example while sitting at a table or visiting the bathroom, vital signs and contextual parameters cannot be derived resulting in periods of missing data.
Finally, as this study is conducted in a Western European setting, the distribution of skin tones may be limited. Because rPPG relies on detecting subtle pulsatile colour changes in exposed skin, which may be less pronounced in individuals with higher Fitzpatrick skin types, signal extraction may be more challenging in these individuals [42]. As a result, the accuracy of heart rate and heart rhythm estimation may vary across skin tones and our findings may not completely generalise to more diverse populations [43].
Supporting information
S1 Table. Overview of postoperative complications and diagnostic criteria included in the ADVANCE-FORSEE study.
https://doi.org/10.1371/journal.pone.0362169.s001
(DOCX)
References
- 1. Analysetool: Hart & Vaatcijfers. https://www.hartenvaatcijfers.nl/analysetool/cardiochirurgie-e543b. Accessed 2026 September 30.
- 2. El Moheb M, Bitar ER, Putman K, Lain W, Weber M, Noona S, et al. Real-time dynamic prediction of mortality and renal replacement therapy after cardiac surgery using a time-series deep learning model. J Thorac Cardiovasc Surg. 2026;:S0022-5223(26)01234-1. pmid:42668112
- 3. Churpek MM, Adhikari R, Edelson DP. The value of vital sign trends for detecting clinical deterioration on the wards. Resuscitation. 2016;102:1–5. pmid:26898412
- 4. Andersen LW, Kim WY, Chase M, Berg KM, Mortensen SJ, Moskowitz A, et al. The prevalence and significance of abnormal vital signs prior to in-hospital cardiac arrest. Resuscitation. 2016;98:112–7. pmid:26362486
- 5. Eddahchouri Y, Koeneman M, Plokker M, Brouwer E, van de Belt TH, van Goor H, et al. Low compliance to a vital sign safety protocol on general hospital wards: A retrospective cohort study. Int J Nurs Stud. 2021;115:103849. pmid:33517078
- 6. Jerry EE, Bouwman ARA, van Esch EMG, Richardson R, Nienhuijs SW. Remote Monitoring With a Reusable Device Upon Implementation on a Surgical Department (REQUEST Trial). World J Surg. 2026;50(3):676–83. pmid:41672938
- 7. Eddahchouri Y, Peelen RV, Koeneman M, Touw HRW, van Goor H, Bredie SJH. Effect of continuous wireless vital sign monitoring on unplanned ICU admissions and rapid response team calls: a before-and-after study. Br J Anaesth. 2022;128(5):857–63. pmid:35282866
- 8. Posthuma LM, Downey C, Visscher MJ, Ghazali DA, Joshi M, Ashrafian H, et al. Remote wireless vital signs monitoring on the ward for early detection of deteriorating patients: A case series. Int J Nurs Stud. 2020;104:103515. pmid:32105974
- 9. Mølgaard J, Grønbæk KK, Rasmussen SS, Eiberg JP, Jørgensen LN, Achiam MP, et al. Continuous Vital Sign Monitoring at the Surgical Ward for Improved Outcomes After Major Noncardiac Surgery: A Randomized Clinical Trial. Anesth Analg. 2025;141(4):807–17. pmid:40591492
- 10. Diao JA, Marwaha JS, Kvedar JC. Video-based physiologic monitoring: promising applications for the ICU and beyond. NPJ Digit Med. 2022;5(1):26. pmid:35256730
- 11. Varma M, Sequeira T, Naidu NKS, Mallya Y, Sunkara A, Patil P, et al. Contactless monitoring of respiratory rate (RR) and heart rate (HR) in non-acuity settings: a clinical validity study. BMJ Open. 2022;12(12):e065790. pmid:36564107
- 12. Jorge J, Villarroel M, Tomlinson H, Gibson O, Darbyshire JL, Ede J, et al. Non-contact physiological monitoring of post-operative patients in the intensive care unit. NPJ Digit Med. 2022;5(1):4. pmid:35027658
- 13. Cramer IC, Cox EGM, de Kok JWTM, Koeze J, Visser M, Bouma HR, et al. Quantification of facial cues for acute illness: a systematic scoping review. Intensive Care Med Exp. 2025;13(1):17. pmid:39946087
- 14. Van Gastel M, Stuijk S, Overeem S, Van Dijk JP, Van Gilst MM, De Haan G. Camera-based vital signs monitoring during sleep – a proof of concept study. IEEE Journal of Biomedical and Health Informatics. 2021;25:1409–18.
- 15. van Esch RJC, Cramer IC, Verstappen C, Kloeze C, Bouwman RA, Dekker L, et al. Camera-Based Continuous Heart and Respiration Rate Monitoring in the ICU. Applied Sciences. 2025;15(7):3422.
- 16. Cramer I, van Esch R, Verstappen C, Kloeze C, van Bussel B, Stuijk S, et al. Accuracy of remote, video-based supraventricular tachycardia detection in patients undergoing elective electrical cardioversion: a prospective cohort. J Clin Monit Comput. 2025;39(5):821–9. pmid:39881085
- 17. Handboeken | NHR. https://nhr.nl/handboeken/#handleidingen. Accessed 2026 September 30.
- 18. Hu P, Ramanan D. Finding Tiny Faces. arXiv. 2016.
- 19. Wang W, Den Brinker AC, Stuijk S, De Haan G. Algorithmic principles of remote PPG. IEEE Transactions on Biomedical Engineering. 2016;64:1479–91.
- 20. Wang W, Den Brinker AC, De Haan G. Discriminative Signatures for Remote-PPG. IEEE Transactions on Biomedical Engineering. 2020;67:1462–73.
- 21. Wang W, den Brinker AC. Algorithmic insights of camera-based respiratory motion extraction. Physiol Meas. 2022;43(7):10.1088/1361-6579/ac5b49. pmid:35255488
- 22. Elgendi M, Martinelli I, Menon C. Optimal signal quality index for remote photoplethysmogram sensing. npj Biosensing. 2024;1(1).
- 23. Babac S, Vosters LPJ, Vullings R, Zinger S, van Gastel MJH. Machine learning-based remote PPG signal quality assessment for in-vehicle driver monitoring. Biomedical Signal Processing and Control. 2026;119:109869.
- 24. Liu S, Huang X, Fu N, Li C, Su Z, Ostadabbas S. Simultaneously-collected multimodal lying pose dataset: Enabling in-bed human pose monitoring. IEEE Transactions on Pattern Analysis and Machine Intelligence. 2023;45:1106–18.
- 25. Becker ML, Hurkmans HL, Verhaar JAN, Bussmann JBJ. Monitoring postures and motions of hospitalized patients using sensor technology: a scoping review. Ann Med. 2024;56(1):2399963. pmid:39239877
- 26. Peng Z, van de Sande D, Lorato I, Long X, Liang R-H, Andriessen P, et al. A Comparison of video-based methods for neonatal body motion detection. Annu Int Conf IEEE Eng Med Biol Soc. 2022;2022:3047–50. pmid:36086375
- 27. Forte C, Voinea A, Chichirau M, Yeshmagambetova G, Albrecht LM, Erfurt C, et al. Deep learning for identification of acute illness and facial cues of illness. Front Med (Lausanne). 2021;8:661309. pmid:34381793
- 28. Chen T, Guestrin C. XGBoost: A scalable tree boosting system. 2016.
- 29. Sinha S, Dong T, Dimagli A, Judge A, Angelini GD. A machine learning algorithm-based risk prediction score for in-hospital/30-day mortality after adult cardiac surgery. Eur J Cardiothorac Surg. 2024;66(4):ezae368. pmid:39374541
- 30. Hochreiter S, Schmidhuber J. Long short-term memory. Neural Computation. 1997;9(8):1735–80.
- 31. Naemi A, Schmidt T, Mansourvar M, Wiil UK. Personalized predictive models for identifying clinical deterioration Using LSTM in emergency departments. Stud Health Technol Inform. 2020;275:152–6. pmid:33227759
- 32. Peduzzi P, Concato J, Kemper E, Holford TR, Feinstein AR. A simulation study of the number of events per variable in logistic regression analysis. J Clin Epidemiol. 1996;49(12):1373–9. pmid:8970487
- 33. Ball L, Costantino F, Pelosi P. Postoperative complications of patients undergoing cardiac surgery. Curr Opin Crit Care. 2016;22(4):386–92. pmid:27309972
- 34. Saikevičius L, Raudonis V, Dervinis G, Baranauskas V. Non-contact vision-based techniques of vital sign monitoring: Systematic review. Sensors (Basel). 2024;24(12):3963. pmid:38931747
- 35. Allado E, Poussel M, Renno J, Moussu A, Hily O, Temperelli M, et al. Remote photoplethysmography is an accurate method to remotely measure respiratory rate: A hospital-based trial. J Clin Med. 2022;11(13):3647. pmid:35806932
- 36. Ahmad Hatib NA, Lee JH, Chong S-L, Sng QW, Tan VSR, Ong GY-K, et al. A two-phased study on the use of remote photoplethysmography (rPPG) in paediatric care. Ann Transl Med. 2024;12(3):46. pmid:38911566
- 37. Villarroel M, Jorge J, Meredith D, Sutherland S, Pugh C, Tarassenko L. Non-contact vital-sign monitoring of patients undergoing haemodialysis treatment. Sci Rep. 2020;10(1):18529. pmid:33116150
- 38. de Vries NM, Smilowska K, Hummelink J, Abramiuc B, van Gilst MM, Bloem BR, et al. Exploring the Parkinson patients’ perspective on home-based video recording for movement analysis: A qualitative study. BMC Neurol. 2019;19(1):71. pmid:31029123
- 39. Verstappen C, Cramer IC, Van Esch RJC. Continuous video-based monitoring of vital signs using smart cameras: a qualitative study of patient and healthcare professional perspectives. Journal Title Not Provided. 2023.
- 40. Coaston TN, Vadlakonda A, Mallick S, Aguayo E, Hallare J, Sanaiha Y, et al. Decade-long variation in the development of complications after cardiac surgery across the United States. Surgery. 2025;183:109387. pmid:40344990
- 41. Udzik J, Sienkiewicz S, Biskupski A, Szylińska A, Kowalska Z, Biskupski P. Cardiac complications following cardiac surgery procedures. JCM. 2020;9:3347.
- 42. Dasari A, Prakash SKA, Jeni LA, Tucker CS. Evaluation of biases in remote photoplethysmography methods. NPJ Digit Med. 2021;4(1):91. pmid:34083724
- 43. Bondarenko M, Menon C, Elgendi M. Demographic bias in public remote photoplethysmography datasets. NPJ Digit Med. 2025;8(1):593. pmid:41038972