학술

Segmentation of sparse coronary artery calcifications in computed tomography via 2.5D multi-slice feature fusion

PLOS ONE
CC BY
이 매체는 공공·자유 라이선스로 본문을 직접 표시합니다.

Figures
Abstract
Objective
Accurate segmentation of coronary artery calcification (CAC) on computed tomography (CT) is critical for reliable cardiovascular risk assessment but remains challenging due to the small and sparse nature of calcified lesions. Although 3D models improve inter-slice consistency, their computational and memory demands motivate alternatives for high-resolution CT segmentation. This study investigates whether the essential inter-slice continuity required for CAC segmentation can be recovered using a reusable 2.5D design compatible with standard 2D networks.
Methods
We propose a 2.5D segmentation framework that augments conventional 2D encoder–decoder architectures with a localized multi-slice feature fusion module. The framework selectively restores inter-slice continuity by refining a reference slice through self-attention and incorporating anatomically aligned context from its immediate neighboring slices via cross-attention, without volumetric processing. The module is encoder-agnostic and plug-and-play, enabling seamless integration into both convolutional and Transformer-based backbones. The approach was evaluated using patient-level five-fold cross-validation on a public CAC dataset comprising 433 cardiac-gated CT scans with vessel-wise annotations.
Results
Across all evaluated backbones, the proposed framework consistently improved mean Dice Similarity Coefficient and mean Intersection over Union relative to paired 2D baselines, with additional parameters and computation. The largest class-wise gains were observed in underrepresented artery categories. Attention map analysis provided qualitative support for anatomically coherent inter-slice aggregation. Comparisons with the evaluated 3D models showed competitive segmentation performance with shorter inference times and generally lower peak GPU memory.
Conclusion
This study demonstrates that localized inter-slice continuity can be effectively incorporated into 2D CAC segmentation frameworks without full volumetric processing. The findings support technical feasibility in the evaluated cohort, while external validation and assessment of downstream calcium scoring are needed before clinical application.
Citation: Pi S-W, Sim J-H, Lee B-D (2026) Segmentation of sparse coronary artery calcifications in computed tomography via 2.5D multi-slice feature fusion. PLoS One 21(11): e0363737. https://doi.org/10.1371/journal.pone.0363737
Editor: Kumaradevan Punithakumar, University of Alberta, CANADA
Received: December 22, 2025; Accepted: November 12, 2026; Published: November 25, 2026
Copyright: © 2026 Pi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: The study-generated numerical data underlying the reported segmentation, lesion-detection, and inference-time analyses are publicly available in Zenodo (doi: 10.5281/zenodo.23582377). These include out-of-fold patient-level segmentation scores, lesion-detection counts for the representative models, per-scan inference-time measurements, and the corresponding model identifiers and patient-level cross-validation fold assignments. The numerical data are released under a CC BY 4.0 license. The deposit includes a README describing the data files. The MSFFM implementation, data-preparation scripts, and code for model evaluation and five-fold result aggregation are available on GitHub at https://github.com/sunwxxpi/Multi-Slice-Feature-Fusion. The original CT images and reference annotations were obtained from the third-party dataset “COCA: Coronary Calcium and Chest CT’s” (doi: 10.71718/ge5g-ds80), provided by the Stanford Center for Artificial Intelligence in Medicine and Imaging (AIMI). The authors obtained access by registering on the AIMI dataset portal and agreeing to the Stanford University School of Medicine Dataset Research Use Agreement; no special access privileges were granted. The original data are not included in the Zenodo deposit because the agreement prohibits redistribution of the dataset or any portion thereof by users. Other researchers can apply for access through the same provider-managed process via the official dataset page (https://aimi.stanford.edu/datasets/coca-coronary-calcium-chest-ct), subject to the provider’s registration and data-use requirements.
Funding: This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. RS-2026-25596421). This research was also supported by Kyonggi University’s Graduate Research Assistantship 2026. We confirm that the funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Competing interests: NO authors have competing interests.
Introduction
Coronary artery calcification (CAC) is a well-established imaging biomarker for cardiovascular risk stratification, closely associated with coronary artery disease and adverse cardiovascular outcomes [1–3]. Computed tomography (CT) is routinely used for CAC assessment, and recent studies have explored automated CAC detection and segmentation using deep learning techniques [4,5]. Vessel-wise segmentation provides lesion localization and delineation for automated calcium quantification and can support image review in cardiovascular risk-assessment workflows [6]. Automating this step could reduce manual workload, although improvements in scoring accuracy and workflow efficiency require separate validation. However, CAC lesions are typically small, sparsely distributed, and occupy only a minute fraction of the image volume, making them particularly challenging to segment reliably.
Anatomical context is particularly relevant to CAC because high-attenuation foci must be assigned to the appropriate coronary artery and distinguished from nearby aortic or valvular calcification [7]. This motivates the hypothesis that adjacent axial slices can provide useful cues about the continuation of calcified foci and surrounding coronary anatomy. Such context may help resolve ambiguities in single-slice interpretation, even when a deposit is visible on only one slice.
Most conventional 2D segmentation models process CT scans slice-by-slice and therefore lack explicit modeling of inter-slice spatial continuity, which can limit the contextual information available for interpreting subtle calcifications [8,9]. While volumetric 3D models incorporate inter-slice context directly, their computational and memory requirements motivate alternatives for high-resolution CT segmentation [10]. As a compromise, 2.5D approaches have been proposed to incorporate adjacent slices while retaining 2D processing efficiency [11].
Existing 2.5D methods differ in the stage and granularity of neighboring-slice fusion. Strategies include attention between slice-level feature representations at multiple scales [12], combined semantic, positional, and slice attention on multiscale features [13], and learned fusion of adjacent input slices before subsequent 2D processing [14]. This motivates an alternative based on reference-conditioned spatial attention at intermediate encoder stages, explicitly preserving the original reference-slice features while selectively incorporating neighboring information.
In this work, we investigate whether the local inter-slice continuity required for CAC segmentation can be recovered through selective adjacent-slice fusion, rather than relying exclusively on full volumetric processing. Based on this premise, we propose a reusable 2.5D feature fusion framework that integrates a multi-slice feature fusion module (MSFFM) into standard 2D segmentation networks. MSFFM applies self-attention within the reference slice and cross-attention to its immediate neighbors in parallel. Cross-attention uses reference features as queries, and the fused outputs are added to the original reference features through a residual connection. This design aims to preserve reference-slice information while selectively incorporating adjacent-slice context for sparse CAC segmentation.
Crucially, the proposed module is encoder-agnostic and plug-and-play, requiring no architectural restructuring of existing 2D backbones. By restricting attention to a small, anatomically meaningful slice neighborhood (±1 slice), the framework limits the extent of inter-slice fusion while retaining the original 2D encoder–decoder pathways. Extensive experiments on a public CAC dataset demonstrate that this targeted 2.5D design consistently improves mean segmentation performance over the evaluated 2D baselines, with particularly pronounced gains in underrepresented artery categories. Attention map analysis further provides qualitative support for spatially coherent inter-slice aggregation.
Overall, this work presents a reusable 2.5D framework that incorporates localized inter-slice context into standard 2D architectures for CAC segmentation, aiming to improve the accuracy–efficiency trade-off relative to full volumetric processing.
Materials and methods
Datasets
Our experiments were conducted using a publicly available CAC dataset [15], consisting of gated coronary artery CT DICOM images with vessel-wise CAC segmentation annotations. The dataset was originally collected from 451 patients and publicly released as the Coronary Calcium (COCA) Chest CT dataset by the Stanford Center for Artificial Intelligence in Medicine and Imaging (AIMI) (https://aimi.stanford.edu/datasets/coca-coronary-calcium-chest-ct). Eighteen cases were excluded in their entirety because of data or annotation issues: a missing DICOM tag (n = 1), a recorded z-spacing of 0 mm (n = 12), a nonstandard slice spacing of approximately 2.95 mm (n = 1), missing source DICOM files (n = 2), and unnamed regions of interest (n = 2). The remaining 433 cases were included in this study.
Model evaluation was performed using patient-level five-fold cross-validation. For each fold, four partitions were used for training and the remaining partition was held out exclusively for final testing. Identical fold assignments were used for all baseline models, MSFFM-enhanced models, and ablation experiments to ensure paired comparisons.
Annotations exclude the background and are categorized into four vascular classes corresponding to the locations of calcified lesions: Left Coronary Artery (LCA), Left Anterior Descending Artery (LAD), Left Circumflex Artery (LCX), and Right Coronary Artery (RCA). Each CT slice is provided at a fixed in-plane resolution of 512 × 512 pixels. All retained scans had a slice spacing of 3.0 mm. Among the retained scans, artery-negative status was defined at the patient–artery level according to the released annotations: no calcification was annotated in the corresponding artery on any slice. Cases with identified annotation errors were excluded rather than classified as artery-negative. An artery-negative case could contain calcification in other arteries. Table 1 summarizes the numbers of cases with annotated calcification and the numbers of slices with and without ground-truth calcification for each artery category.
2.5D segmentation framework
We propose a novel 2.5D segmentation framework that captures spatial continuity by modeling interactions between a reference slice and its adjacent slices using the MSFFM. The module combines self-attention within the reference slice and cross-attention with neighboring slices, allowing the network to learn localized inter-slice dependencies while maintaining computational efficiency. The output feature map from the MSFFM preserves the spatial resolution of the input, enabling seamless integration into existing 2D segmentation architectures without requiring structural modifications.
The proposed MSFFM consists of two main components: (a) a self-attention mechanism applied to the reference slice () and (b) cross-attention mechanisms operating between the reference slice and its neighboring slices ( and ). The final output of the MSFFM, can be formulated as a function of these three input feature maps:
Fig 1 illustrates the MSFFM architecture, highlighting the self-attention operation, denoted as , applied to the reference slice, and the cross-attention operations, and that model the relationships between the reference slice and its neighboring slices.
The feature map is represented as a tensor, where denotes matrix multiplication, element-wise summation, and channel-wise concatenation. Blue boxes indicate 1 1 convolutions, which incorporate a bottleneck structure that reduces the number of channels in the input feature map by half.
Self-attention in reference slice
The submodule applies self-attention to the reference slice () to refine its feature representation by capturing global contextual dependencies. To achieve this, Query (), Key () and Value () components are derived from using trainable convolution transformations. Within the Multi-Head Attention (MHA) [16], is projected into Query, Key, and Value sets for distinct attention heads (subspaces) as follows:
where are trainable projection matrices specific to each attention head . MHA enables independent attention computations within each head and their outputs are subsequently aggregated. Conceptually, the collection of all head-specific Query, Key, and Value matrices can be denoted as:
Next, pairwise similarities are computed using the inner product of the Query and Key matrices for each head, followed by softmax normalization to derive the attention map . This map quantifies the relationships between all spatial positions within itself. The attention map for each head is computed as:
Each attention map is subsequently applied to weight the corresponding Value matrix . The outputs from all heads are concatenated channel-wise using a operation. Finally, a convolution, represented by the projection matrix , is applied to the concatenated features to produce the final self-attended output .
This enables the model to incorporate long-range contextual information within the reference slice, enhancing its internal spatial representation.
Cross-attention with neighboring slices
The submodule employs cross-attention to capture spatial dependencies between the reference slice and a neighboring slice , where indicates either the previous or next slice. Unlike self-attention, where Query, Key, and Value components are all derived from , cross-attention extracts Query components from while obtaining Key and Value components from the neighboring slice . Following the MHA framework, (for Query) and (for Key and Value) are projected into distinct attention heads (subspaces). For each head , the Query (), Key (), and Value () matrices are computed as:
where , , are trainable projection matrices. Notably projects , while and project . These matrices are specific to each head and the type of neighboring slice (previous or next). Similar to self-attention, MHA enables independent attention computations for each head. Conceptually, the collection of all head-specific Query, Key, and Value matrices can be denoted as:
Next, the attention map for each head quantifies the similarity between the Query matrices (from ) and the Key matrices (from ). This computation involves taking the dot product of Query and Key matrices, followed by softmax normalization. Given that and have spatial dimensions , the attention map has dimensions , representing the relationships between all positions in and all positions in . The attention map is computed as:
As with the self-attention mechanism, this approach enables efficient capture of long-range dependencies. The resulting attention map is then used to weight the corresponding Value matrix . The outputs from all heads, , are concatenated channel-wise. Finally, a convolution, represented by the projection matrix , is applied to the concatenated features to generate the final cross-attended feature representation .
This mechanism captures spatially aligned inter-slice dependencies, enabling the model to attend to relevant features in adjacent slices.
Feature fusion
Following the self-attention and cross-attention operations, the resulting attention outputs are concatenated along the channel dimension. Subsequently, a convolution is applied to restore the number of channels to that of the original input dimension. This process can be formulated as follows.
Here, denotes the convolution, which adjusts the number of channels after concatenation, ensuring that maintains the same channel dimension as the input feature map (thus enabling the subsequent residual connection). Furthermore, the final output of the MSFFM incorporates a residual connection [17], in which the original feature map of the reference slice, , is added element-wise to the attention-enhanced feature map, . This design preserves the original reference slice features while integrating the attention-enhanced information captured by MSFFM. The final output of the MSFFM can be expressed as follows.
Importantly, the MSFFM is encoder-agnostic and can be integrated into existing 2D segmentation networks without architectural modification. By restricting feature fusion to a reference slice and its immediate neighboring slices, MSFFM is designed to incorporate localized inter-slice context without requiring full-volume processing. Unlike full 3D segmentation models, which operate on volumetric inputs, the proposed module performs attention-based fusion on selected 2D feature maps, with additional computation arising from neighboring-slice encoding and the inserted fusion stages. The empirical computational trade-off of this design is evaluated in the Results section using parameter count, GFLOPs, and inference time.
Implementation and training details
A consistent training procedure was maintained for the nine baseline–MSFFM pairs. Models were trained using the AdamW optimizer [18] with an initial learning rate of and PolynomialLR scheduler [19]. The loss function combined Dice and Cross Entropy losses with equal weights of 0.5. All 2D and 2.5D models were trained on the original DICOM slices without cropping or resizing.
For the baseline–MSFFM pairs, CT intensities were clipped to [1017, 1801], corresponding to the 0.5th and 99.5th percentiles of foreground intensities in the COCA-specific nnU-Net configuration [20], and standardized using a mean of 1222.871826 and a standard deviation of 132.643890. These fixed parameters were applied to both models in each pair.
For the default ±1-slice MSFFM configuration, each input comprised a reference slice and its immediate neighbors, with the reference-slice mask as the segmentation target. The previous, reference, and next slices were processed by the same encoder with shared weights. MSFFM fused the corresponding features at Stage 3 and 4, with spatial resolutions of 32 × 32 and 16 × 16, respectively. At each selected stage, the fused output replaced the reference-slice feature map in the original decoder pathway; features from other stages were unchanged.
For this configuration, reference indices ranged from 1 to N-2 (zero-based), where N denotes the number of slices in the scan. The first and last slices provided neighboring-slice context only, without padding or slice replication. Paired 2D baselines used the same reference slices.
In the MSFFM implementation, Query, Key, and Value projections were implemented using 1 × 1 convolutions with a bottleneck ratio of 0.5, reducing the channel dimension by half before attention computation. The number of heads in the MHA mechanism was set to 8. For each selected encoder stage, feature maps were flattened over the spatial dimension to compute attention across H × W spatial positions. Self-attention was applied within the reference-slice feature map, whereas cross-attention used the reference-slice feature map as the Query and the neighboring-slice feature maps as the Key and Value. Self-attention and the two cross-attention branches operated in parallel on the same reference-slice feature map; the self-attended output was not used as input to the cross-attention branches. The resulting self- and cross-attended outputs were concatenated, projected using a 1 × 1 convolution, and added to the original reference-slice feature map through a residual connection.
For the baseline–MSFFM pairs, data augmentation techniques were limited to basic transformations, including horizontal and vertical flipping, as well as random rotation within 10 degrees. For 2.5D inputs, the same geometric augmentation was applied consistently to the reference slice, adjacent slices, and the corresponding reference-slice mask. The batch size was set to 16.
For each cross-validation iteration, preliminary training runs were conducted using only the four training partitions. The training duration was determined empirically by examining the training-loss trajectories and identifying the epoch at which the training loss ceased to decrease. The final model was then retrained on the same four partitions for the selected number of epochs and evaluated on the remaining test partition. The test partition was not used to determine the training duration or select a checkpoint. The same procedure was applied to all models except 2.5D-nnU-Net and 3D-nnU-Net, which were trained for a fixed 1,000 epochs and tested using their final checkpoints. Their internal validation subsets were drawn exclusively from the four training partitions.
Competing methods were implemented using their publicly available official code. Method-specific hyperparameters followed author-recommended or automatically conFigd settings, except for the training-duration procedure described above and adaptations to input channels, output classes, and input or patch size. The 2.5D methods (CAT-Net [12], CSAM [13], SegMate [14], and 2.5D-nnU-Net [20]) used the reference slice and its immediate neighbors; 2.5D-nnU-Net stacked these three slices as input channels of the automatically conFigd 2D nnU-Net model. SegFormer3D [21] and LHU-Net [22] used volumetric patches of 32 × 192 × 192, whereas 3D-nnU-Net [20] used 32 × 384 × 320 patches (Table 5). For the nnU-Net baselines, preprocessing, network topology, patch size, and batch size were determined by the nnU-Net self-configuring pipeline. These settings were not selected using the held-out test folds, and all methods used identical patient-level folds and evaluation rules.
Final segmentations from the paired 2D baselines and MSFFM-based 2.5D models were obtained by pixel-wise argmax over the softmax probabilities for background and the four artery classes. No additional thresholding, connected-component filtering, morphological operations, or test-time augmentation was applied.
All experiments were conducted on a single NVIDIA A100 GPU. The baseline–MSFFM models were implemented using PyTorch and the segmentation_models.pytorch library. The MSFFM implementation and data-preparation scripts are available at https://github.com/sunwxxpi/Multi-Slice-Feature-Fusion.
Evaluation metrics
Segmentation performance was evaluated using the Dice Similarity Coefficient (DSC) and mean Intersection over Union (mIoU). DSC and IoU were defined as and , respectively, where TP, FP, and FN denote true-positive, false-positive, and false-negative pixel counts. Both metrics assess spatial agreement between the prediction and ground truth; however, IoU is generally considered a stricter overlap measure because the same segmentation error results in a lower IoU value than DSC. In this study, “IoU” refers to class-wise or artery-specific Intersection over Union values, whereas “mIoU” denotes the mean IoU across artery categories, with the aggregation procedure specified below. Together, DSC and mIoU summarize spatial agreement between the predicted and annotated CAC regions.
For each patient and artery category, the predicted reference-slice masks were stacked into a scan-level volume, and TP, FP, and FN were summed over all reference slices of the scan before calculating DSC and IoU; slice-level scores were not averaged. Accordingly, false positives on slices without ground-truth (GT) calcification for that artery contributed to DSC and IoU, and an empty prediction for an artery with GT calcification yielded DSC and IoU values of zero. Patient–artery pairs without GT calcification were excluded from the corresponding artery-specific average.
Within each test fold, patient-level scores were averaged separately for each artery category across eligible patients. Overall DSC and mIoU were then calculated as the unweighted means of the four artery-specific averages. Results are reported as the mean ± standard deviation of the corresponding fold-level scores across the five folds.
For lesion-level evaluation, lesions were defined per artery as 3D connected components (26-connectivity) in masks stacked from all reference slices, including those without GT calcification. Within each scan, overlapping GT and predicted lesions of the same artery were matched one-to-one to maximize the number of matches. Unmatched GT and predicted lesions were counted as missed and FP lesions, respectively. Sensitivity and precision were calculated per artery and test fold as the matched-pair count divided by the total GT and predicted lesion counts, respectively. FP lesions per scan were calculated within the corresponding artery-negative subset or full eligible set by dividing the total FP count by the number of scans.
For each overlap metric, statistical significance was assessed using two-sided Wilcoxon signed-rank tests on paired out-of-fold patient-level scores pooled across the five folds, rather than fold-level averages. Each patient contributed scores from its held-out test fold, with identical fold assignments and GT-based eligibility criteria for each baseline–MSFFM pair. Artery-specific tests used the corresponding patient–artery scores. Overall tests used each patient’s unweighted mean across GT-positive artery categories, excluding patients with no such category. Thus, overall tests compared patient-level scores, whereas tabulated overall results equally averaged artery-specific means; because their weighting differs, the mean patient-level overall score need not equal the tabulated overall mean.
Multiplicity was controlled using the Holm step-down procedure, applied separately to each metric within three comparison families: overall baseline–MSFFM comparisons, artery-specific baseline–MSFFM comparisons, and ablation comparisons against the baseline. A Holm-adjusted p-value < 0.05 was considered statistically significant.
Mean paired differences (Δ) were calculated from the corresponding out-of-fold patient-level scores, with contrast directions specified in the tables. The different aggregation procedures described above assign different effective weights to patient–artery scores; Δ need not equal the difference between the tabulated means. The 95% confidence intervals for Δ were estimated using 10,000 paired patient-level bootstrap resamples drawn with replacement from eligible patients pooled across the five folds, without multiplicity adjustment.
Parameter counts were reported in millions, with shared encoder weights counted once. For the paired baseline–MSFFM and ablation analyses, GFLOPs were calculated per model input corresponding to one reference-slice prediction, including any neighboring-slice context required by the configuration. Repeated passes through the shared encoder contributed to computation without duplicating encoder parameters. For comparisons with competing 2.5D and 3D methods, scan-level GFLOPs were calculated by summing the computation over all reference-slice inputs or overlapping volumetric patches required to process each scan.
Inference time was measured per scan on preprocessed inputs using a single NVIDIA A100 GPU, excluding data loading, preprocessing, and post-processing. Scan times were averaged within each test fold and summarized as the mean ± standard deviation across the five fold-level means. Peak allocated GPU memory was measured for all models in the competing-method comparison during a single forward pass with batch size 1 and FP16 autocast. This measurement characterized forward-pass memory rather than whole-scan processing or training memory requirements.
Results
Comparative performance of MSFFM-enhanced architecture
To evaluate the effectiveness and architectural generalizability of the proposed MSFFM, we conducted experiments using multiple encoder–decoder combinations. U-Net [23] and SegFormer [24] were selected as representative decoders, covering a conventional medical segmentation architecture and a lightweight MLP-based decoder, respectively. Each decoder was paired with four different encoder backbones: ResNet-50 [17], DenseNet-201 [25], EfficientNet-b4 [26], and Mix Transformer (MiT)-b2 [24]. In addition, the efficient multi-scale cascaded fully-convolutional attention decoder (EMCAD) [27], a recent multi-scale convolutional attention decoder for medical image segmentation, was included as a strong comparative architecture, using Pyramid Vision Transformer v2 (PVTv2)-b2 [28] as its encoder.
Table 2 compares DSC and mIoU performance across different encoder-decoder architectures, with and without the MSFFM, using patient-level five-fold cross-validation. MSFFM increased the observed mean DSC and mIoU in all encoder–decoder combinations, and in paired analyses of out-of-fold patient-level scores, the improvements remained statistically significant after Holm adjustment in six combinations for DSC and five for mIoU. MiT-b2-UNet showed the largest observed mean paired improvements: + 0.245 for DSC (95% CI, + 0.223 to +0.266) and +0.201 for mIoU (95% CI, + 0.183 to +0.219). These confidence intervals were obtained by patient-level bootstrap resampling without multiplicity adjustment. PVTv2-b2-EMCAD-MSFFM achieved the highest observed mean performance among the evaluated combinations, with a DSC of 0.758 ± 0.011 and an mIoU of 0.666 ± 0.020. Its improvements over the corresponding baseline remained significant for both metrics (Holm-adjusted p < 0.001 for each). These results support the utility of MSFFM across multiple encoder–decoder architectures under the evaluated protocol, although the magnitude of improvement and the statistical evidence varied by architecture.
Table 3 further examines class-wise performance for two representative U-Net-based models, ResNet-50-UNet and MiT-b2-UNet. These two models were selected as representative cases because their baseline versions yielded zero DSC and IoU for LCA in both models and for LCX in MiT-b2-UNet. To investigate these zero scores, label mapping, reference-slice masks, sample lists, and patient-level fold assignments were examined. No label inconsistencies or duplicated or missing reference slices were identified, and all four artery categories were represented in the combined training set of each cross-validation iteration. LCA and LCX appeared in 226 and 1,024 of the 20,790 reference slices, respectively (Table 1). These categories accounted for 4.36% and 17.95% of foreground pixels, respectively. Aggregate training losses had plateaued by the end of training in all five folds.
Neither baseline produced LCA predictions in any test scan. Ground-truth LCA pixels were classified predominantly as background (78.8% for ResNet-50-UNet and 68.8% for MiT-b2-UNet), with the remainder assigned to LAD or LCX. In MiT-b2-UNet, ground-truth LCX pixels were classified as background (97.9%) or LAD (2.1%), with none correctly assigned to LCX. Unlike LCA, however, LCX predictions were produced, yielding zero lesion sensitivity and precision but 0.016 ± 0.005 FP lesions per eligible scan (Table 4(c)), consistent with false-positive-only lesion predictions. Thus, the zero scores reflected absent LCA predictions in both baselines and incorrect LCX predictions without ground-truth overlap in MiT-b2-UNet.
MSFFM yielded nonzero DSC and IoU for these categories, with statistically significant improvements for LCA in both models and for LCX in MiT-b2-UNet after Holm adjustment. However, the effect of MSFFM was not uniformly positive across all artery categories: while ResNet-50-UNet showed additional improvements in RCA and modest changes in LAD and LCX, MiT-b2-UNet showed statistically significant decreases in DSC and IoU for LAD and RCA after Holm adjustment. Under the evaluated training protocol, the largest class-wise gains were observed in categories with zero baseline overlap, while the effect of MSFFM depended on the baseline architecture and artery category.
Table 4 summarizes false detections and lesion-level performance for the two representative models. In ResNet-50-UNet, adding MSFFM increased lesion sensitivity and precision for LAD, LCX, and RCA and reduced the number of FP lesions per scan in both artery-negative and all eligible cases. For LCA, which the baseline never predicted, MSFFM achieved 52.1% sensitivity and 76.0% precision, with 0.032 FP lesions per artery-negative scan. In MiT-b2-UNet, MSFFM recovered the LCA and LCX categories, increasing lesion sensitivity from 0% to 41.0% and 71.7%, respectively, accompanied by more FP lesions across all four artery categories and lower lesion sensitivity and precision for LAD and RCA, consistent with the class-wise trends in Table 3. Across the evaluated model–artery combinations, the highest five-fold mean FP counts were 0.260 per artery-negative scan and 0.502 per eligible scan. Thus, improved lesion recovery could be accompanied by additional false detections, with the balance depending on the baseline architecture and artery category.
Fig 2 shows representative qualitative results demonstrating the effectiveness of the proposed MSFFM. Fig 2a shows the original axial CT image, and Fig 2b shows the corresponding ground-truth segmentation mask. In Fig 2b, the red bounding box contains a small LCA-class lesion (blue) and a segment of an LAD-class lesion (green). Fig 2c presents the predictions of the baseline ResNet-50-UNet model. This model successfully detects major vascular lesions, including the more prevalent and widespread LAD-class lesion (green), but fails to identify the smaller LCA-class lesion (blue) within the highlighted region. In contrast, Fig 2d presents the results of ResNet-50-UNet with MSFFM, revealing that the MSFFM-enhanced model successfully detects the previously missed small lesion. Figs 2e and 2f show the predictions of the baseline EMCAD model and its MSFFM-enhanced variant (PVTv2-b2-EMCAD-MSFFM), respectively. Although the baseline PVTv2-b2-EMCAD appears to better capture the LCA lesion within the red bounding box than the baseline ResNet-50-UNet, the MSFFM-enhanced model provides more spatially consistent delineation with fewer visually apparent errors (Fig 2f). This example illustrates differences in lesion recovery and delineation between the baseline and MSFFM-enhanced predictions.
In the segmentation masks, blue indicates the LCA-class calcification and green indicates the LAD-class calcification. The red bounding box marks the region containing a small LCA lesion, and the enlarged inset shows this region in detail. The MSFFM-integrated models show improved detection and delineation of the small LCA lesion compared with the corresponding baseline models. (a) Input Image (b) Ground Truth (c) ResNet-50-UNet (d) ResNet-50-UNet-MSFFM (e) PVTv2-b2-EMCAD (f) PVTv2-b2-EMCAD-MSFFM.
Fig 3 visualizes attention maps generated by the MSFFM when integrated into the ResNet-50-UNet model. The top row shows axial CT images of the previous slice, reference slice, and next slice, with ground-truth annotations overlaid and the query patch indicated by the red bounding box in the reference slice. The corresponding attention maps are shown for two encoder stages: Stage 3 with a 32 × 32 feature resolution and Stage 4 with a 16 × 16 feature resolution. From left to right, the heatmaps represent cross-attention between the reference query patch and the previous slice, self-attention within the reference slice, and cross-attention between the reference query patch and the next slice. The self-attention maps appear to emphasize relevant anatomical structures within the reference slice, whereas the cross-attention maps highlight spatially corresponding regions in adjacent slices. This pattern suggests that MSFFM incorporates inter-slice contextual information that is anatomically aligned with the reference lesion region. Compared with Stage 4, the Stage 3 maps retain relatively finer spatial detail because of their higher feature resolution, while the Stage 4 maps provide a more compact representation at a deeper encoder level. Together, these visualizations provide qualitative support for the role of MSFFM in integrating localized adjacent-slice information.
The top row shows the previous slice, reference slice, and next slice with ground-truth calcification annotations. The red box in the reference slice denotes the query patch used to generate the attention responses. The middle and bottom rows show attention maps at Stage 3 (32 × 32) and Stage 4 (16 × 16), respectively. From left to right, the maps represent cross-attention between the reference query patch and the previous slice, self-attention within the reference slice, and cross-attention between the reference query patch and the next slice. Warmer colors indicate higher attention responses, whereas cooler colors indicate lower attention responses.
Comparison with representative 2.5D and 3D segmentation baselines
The proposed MSFFM-enhanced models were compared with representative 2.5D and 3D segmentation baselines using identical patient-level five-fold cross-validation assignments and evaluation metrics. The 2.5D baselines included CAT-Net, CSAM, SegMate, and 2.5D-nnU-Net, whereas the 3D baselines included SegFormer3D, LHU-Net, and 3D-nnU-Net. Table 5(a) reports DSC, mIoU, parameter count, GFLOPs per scan, inference time, and peak allocated GPU memory; Table 5(b) reports paired differences in patient-level scores with bootstrap 95% confidence intervals.
Both MSFFM-enhanced models yielded higher observed mean DSC and mIoU than CAT-Net, CSAM, and SegMate. PVTv2-b2-EMCAD-MSFFM achieved the highest observed mean performance among the evaluated 2.5D methods, with a DSC of 0.758 ± 0.011 and an mIoU of 0.666 ± 0.020. ResNet-50-UNet-MSFFM had a slightly higher mean DSC but a slightly lower mean mIoU than 2.5D-nnU-Net (0.721 versus 0.720 and 0.637 versus 0.640, respectively). Relative to 2.5D-nnU-Net, PVTv2-b2-EMCAD-MSFFM showed mean paired differences of +0.036 for DSC (95% CI, + 0.013 to +0.060) and +0.026 for mIoU (95% CI, −0.002 to +0.054). Both paired confidence intervals for ResNet-50-UNet-MSFFM versus 2.5D-nnU-Net included zero. These bootstrap intervals were not adjusted for multiplicity.
Across all evaluated methods, 3D-nnU-Net achieved the highest observed mean DSC and mIoU (0.783 ± 0.021 and 0.690 ± 0.022, respectively), followed by PVTv2-b2-EMCAD-MSFFM. ResNet-50-UNet-MSFFM had lower mean DSC but similar mean mIoU compared with SegFormer3D and LHU-Net. Artery-specific comparisons (S1 Table) showed that PVTv2-b2-EMCAD-MSFFM had the highest observed mean LCA DSC and IoU among the evaluated 2.5D methods, but lower scores than 3D-nnU-Net. For LCX, both proposed models had lower mean scores than the two nnU-Net baselines. These findings indicate that the relative performance on underrepresented artery categories varied by architecture, artery, and competing method.
Both MSFFM-enhanced models required fewer GFLOPs per scan and shorter inference times than all three evaluated 3D baselines. Compared with 3D-nnU-Net, PVTv2-b2-EMCAD-MSFFM used fewer parameters (30.06 versus 138.29 M), fewer GFLOPs per scan (6,264 versus 648,784), and shorter inference time (3,800 versus 21,130 ms/scan), despite its lower observed overlap scores.
PVTv2-b2-EMCAD-MSFFM also had the lowest measured peak allocated GPU memory among the evaluated methods, at 240.2 MiB for a single forward pass with batch size 1 and FP16 autocast. Computational advantages were not uniform across the 2.5D comparisons: CSAM had shorter inference time, and SegMate required fewer GFLOPs per scan, than either MSFFM-enhanced model. Overall, these results demonstrate architecture-dependent accuracy–efficiency trade-offs under the evaluated conditions, rather than uniform superiority over the competing methods.
Ablation study
To evaluate the effect of MSFFM placement, we integrated the module at different encoder stages in ResNet-50-UNet under the same patient-level five-fold cross-validation setting. As shown in Table 6a, inserting MSFFM at Stage 3 (32 × 32) significantly improved both DSC and mIoU compared with the baseline, whereas insertion at Stage 4 (16 × 16) produced a smaller improvement, with statistical significance observed only for DSC. Joint integration at Stages 3 and 4 yielded the highest observed mean DSC and mIoU among the evaluated placements, with statistically significant improvements over the baseline after Holm adjustment. These observations are consistent with a benefit from combining feature representations across encoder stages under the evaluated protocol.
We next evaluated the effect of the number of neighboring slices used for MSFFM-based inter-slice fusion. As shown in Table 6b, all configurations yielded higher mean DSC and mIoU than the reference-only baseline. After Holm adjustment, DSC improvements remained significant for all three configurations, whereas mIoU improvements remained significant for ±1 and ±2 slices but not for ±3 slices (p = 0.051). The ± 1 slice configuration yielded the highest observed mean DSC and mIoU, whereas extending the context to ±2 or ±3 slices did not improve the observed mean scores and progressively increased computational cost. These results suggest that immediate neighboring slices provide sufficient local continuity for sparse CAC segmentation, while more distant slices may introduce less relevant contextual information and reduce the efficiency of the module.
Finally, we analyzed the contribution of the attention components within MSFFM. As shown in Table 6c, both self-attention and cross-attention improved performance compared with the baseline, indicating that intra-slice feature refinement and inter-slice contextual fusion each contribute to sparse CAC segmentation. Cross-attention alone yielded higher observed mean DSC and mIoU than self-attention alone. The full MSFFM, which combines self-attention and cross-attention, yielded the highest observed mean DSC and mIoU among the evaluated attention configurations, with statistically significant improvements over the baseline after Holm adjustment. These findings support the design rationale of combining reference-slice refinement with adjacent-slice fusion.
All statistical comparisons in Table 6 were performed against the original ResNet-50-UNet baseline, not directly between MSFFM variants. Accordingly, rankings among variants are based on observed mean performance.
Computational complexity and inference-time analysis
To assess the practical overhead introduced by MSFFM, model parameters, GFLOPs per input, and inference time per scan were compared between each 2D baseline and its MSFFM-enhanced counterpart (Table 7). Parameter counts, GFLOPs, and inference times increased across all nine pairs, with the magnitude of the increase depending on the architecture. For ResNet-50-UNet, MSFFM increased the parameter count from 32.51 to 36.45 M, GFLOPs per input from 42.27 to 87.08, and inference time from 321 ± 6–864 ± 17 ms/scan. Thus, the increase in parameter count was accompanied by a larger relative increase in computation and runtime.
Together with the segmentation results in Table 2 and the competing-method comparisons in Table 5, these findings indicate an architecture-dependent accuracy–efficiency trade-off. MSFFM improved mean segmentation performance over the paired 2D baselines at additional computational cost, while the two representative MSFFM-enhanced models required fewer GFLOPs per scan and shorter inference times than the evaluated 3D models. These measurements support technical feasibility within the evaluated cohort and hardware setting, rather than established readiness for clinical deployment.
Discussion and conclusions
This study proposed a 2.5D segmentation framework for CAC that incorporates localized inter-slice context into standard 2D encoder–decoder architectures. Using patient-level five-fold cross-validation, we showed that integrating the MSFFM improved the mean DSC and mIoU across all evaluated encoder–decoder combinations. The improvements were statistically significant in most comparisons, although the magnitude of benefit varied across architectures and artery categories. These findings suggest that localized adjacent-slice fusion can provide useful contextual information for CAC segmentation while preserving the practical advantages of 2D segmentation models.
The main design objective of MSFFM was to recover the local inter-slice continuity of CAC lesions without requiring full-volume processing. CAC deposits are often small, sparsely distributed, and difficult to distinguish from adjacent high-density structures when evaluated on a single axial slice. MSFFM addresses this limitation by combining self-attention within the reference slice with cross-attention to its immediate neighboring slices. The class-wise results support this design rationale: MSFFM was particularly effective in recovering artery categories that were missed by baseline models, including LCA lesions in both representative U-Net-based models and LCX lesions in the MiT-b2-UNet setting. At the same time, the benefit was not uniform across all arteries, with reduced performance observed for LAD and RCA in the MiT-b2-UNet model. Thus, marked gains were observed in artery categories underdetected by the representative baseline models, while effects varied by architecture and artery category.
The expanded ablation study further clarified the contribution of the proposed design. Among the evaluated neighboring-slice configurations, the ± 1-slice configuration combined the highest observed mean DSC and mIoU with the lowest parameter count and GFLOPs. Extending the context to ±2 or ±3 slices did not improve the observed mean scores and increased computational cost. This finding supports the use of immediate neighboring slices to capture local continuity for sparse CAC lesions. The component-level ablation was consistent with complementary roles for self-attention and cross-attention in reference-slice refinement and adjacent-slice contextual fusion, respectively. The full MSFFM yielded the highest observed mean DSC and mIoU among the evaluated attention configurations, supporting their combined use under the evaluated protocol.
Compared with representative 2.5D and 3D segmentation baselines, the proposed MSFFM-enhanced models showed a favorable accuracy–efficiency trade-off. Relative to attention-based 2.5D methods such as CAT-Net and CSAM, MSFFM is distinguished by its reference-preserving design: reference-slice self-attention and cross-attention to immediate neighboring slices operate in parallel. This decoupling of intra-slice refinement and inter-slice fusion is intended to reduce indiscriminate mixing of slice-specific semantics while retaining the local continuity needed for sparse CAC segmentation. Both MSFFM-enhanced models achieved higher observed mean DSC and mIoU than CAT-Net, CSAM, and SegMate, although their relative performance against 2.5D-nnU-Net and the 3D methods varied by architecture. 3D-nnU-Net retained the highest observed mean overlap scores. The class-wise comparison identified a relative strength in LCA segmentation for PVTv2-b2-EMCAD-MSFFM, but this pattern did not extend uniformly to ResNet-50-UNet-MSFFM or to LCX. Thus, recovery of categories missed by paired 2D baselines should not be interpreted as general superiority over competing 2.5D and 3D methods for all underrepresented artery categories. Both MSFFM-enhanced models required fewer GFLOPs per scan and shorter inference times than the evaluated 3D models. For PVTv2-b2-EMCAD-MSFFM, these computational savings were accompanied by lower observed mean DSC and mIoU than 3D-nnU-Net. These findings indicate an accuracy–efficiency trade-off under the evaluated conditions rather than uniformly superior segmentation accuracy.
Frequency-domain segmentation methods represent another relevant line of work in medical image segmentation. These methods introduce Fourier- or wavelet-domain representations to enhance global context modeling, multi-scale feature extraction, or boundary/detail representation [29–31]. They are conceptually complementary to MSFFM. Whereas frequency-domain methods primarily enrich within-image spectral representations, MSFFM operates in the spatial feature domain and focuses on localized inter-slice continuity in CT. Specifically, MSFFM preserves the reference-slice representation and selectively incorporates anatomically aligned adjacent-slice information through cross-attention. Thus, the novelty of MSFFM lies not in frequency-domain feature modeling, but in reference-preserving 2.5D fusion for sparse CAC lesions.
From a translational perspective, improved CAC segmentation may be relevant to downstream calcium scoring. Calcium scoring algorithms, including Agatston scoring, depend on the detected area and density of calcified lesions. Recovering previously missed calcifications may therefore help reduce underestimation of calcific burden in automated scoring workflows. However, lesion recovery was accompanied by architecture- and artery-dependent changes in false detections, so its effect on calcium-score agreement remains to be established. Downstream calcium scoring, risk-category agreement, and clinical outcome prediction were not directly evaluated in this study. Future studies should determine whether the observed segmentation improvements translate into improved calcium score agreement and cardiovascular risk stratification.
Several limitations should be acknowledged. First, evaluation was limited to patient-level five-fold cross-validation within a single public dataset, without a separate stand-alone test set or external validation cohort. Although the held-out test folds were not used to determine training duration or select checkpoints, the highest observed performance among configurations compared within this cohort may be optimistic. These internal cross-validation estimates require confirmation in independent datasets spanning different institutions, scanners, reconstruction protocols, and patient populations. Second, although representative 2.5D and 3D baselines were included, exact equivalence across input contexts is difficult because 2D/2.5D models operate on reference slices with adjacent-slice context, whereas 3D models use local volumetric patches. Third, inference time was measured on a single NVIDIA A100 GPU using preprocessed scans and excluded data loading, preprocessing, and post-processing; therefore, runtime in real-world deployment environments may differ. Fourth, performance was not stratified by lesion size or volume. Improvements in underdetected artery categories therefore should not be interpreted as evidence of a size-specific benefit for smaller lesions. Finally, the applicability of MSFFM to other vascular pathologies, imaging protocols, or sparse lesion segmentation tasks remains to be investigated.
In conclusion, this study demonstrates that localized attention-based fusion of adjacent CT slices can improve overall CAC segmentation within standard 2D segmentation frameworks, with marked gains in artery categories underdetected by the representative 2D baseline models. By combining reference-slice self-attention with neighboring-slice cross-attention, MSFFM provides a practical mechanism for incorporating inter-slice context without full-volume processing. The proposed framework offers a favorable balance between segmentation accuracy and computational efficiency under the evaluated conditions, supporting technical feasibility within the COCA cohort. Clinical deployment remains a future goal requiring independent external validation, assessment of downstream calcium-score and risk-category agreement, and evaluation in clinical workflows.
Supporting information
S1 Table. Class-wise DSC and IoU of the 2.5D and 3D segmentation methods compared in Table 5.
Values are reported as mean ± standard deviation across the five folds of patient-level cross-validation. As in Table 3, class-wise values for each artery category were computed over patients with a nonempty ground truth for that category (n = 149, 382, 246, and 256 for LCA, LAD, LCX, and RCA, respectively), and the overall value is the unweighted mean of the four artery-specific values.
https://doi.org/10.1371/journal.pone.0363737.s001
(DOCX)
References
- 1. Alfaddagh A, El Mugharbil A, Yousef A. Abstract 4123501: coronary artery calcium in asymptomatic arabs: prevalence and distribution. Circulation. 2024;150(Suppl_1).
- 2. K. Sonavane S, Terry N, Fineberg N, Nath H. Comparison of Visual Scoring of Coronary Artery Calcium (CAC) on Coronary Computed Tomography Angiogram (CCTA) to Agatston Score. J Heart Circ. 2015;1(1).
- 3. Marcos Garces V, Minguez Diaz De Alda S, Merenciano-Gonzalez H, Villa-Sanchez CA, Perez-Pelegri M, Gavara J, et al. Incidental detection and quantification of coronary artery calcification in ungated thoracic computed tomography for prognostic assessment. Preliminary results from the ICARUS registry. European Heart Journal. 2024;45(Supplement_1).
- 4. Aguilera-Alvarez J, Martínez-Nolasco J, Olmos-Temois S, Padilla-Medina J, Sámano-Ortega V, Bravo-Sanchez M. Development of a web application for the detection of coronary artery calcium from computed tomography. Appl Sci. 2022;12:12281.
- 5. Mansoor MA, Grindem DJ. Automated coronary artery calcium scoring using convolutional neural networks: enhancing cardiovascular risk assessment in chest CT scans. medRxiv. 2024.
- 6. Eng D, Chute C, Khandwala N, Rajpurkar P, Long J, Shleifer S, et al. Automated coronary calcium scoring using deep learning with multicenter external validation. NPJ Digit Med. 2021;4(1):88. pmid:34075194
- 7. Lessmann N, van Ginneken B, Zreik M, de Jong PA, de Vos BD, Viergever MA, et al. Automatic calcium scoring in low-dose chest CT using deep neural networks with dilated convolutions. IEEE Trans Med Imaging. 2018;37(2):615–25. pmid:29408789
- 8.
Park D, Kim J, Chang Q, Leng S, Zhong L, Baskaran L. RICAU-NET: Residual-Block Inspired Coordinate Attention U-Net for Segmentation of Small and Sparse Calcium Lesions in Cardiac CT. In: 2025 IEEE 22nd International Symposium on Biomedical Imaging (ISBI), 2025. 1–5. https://doi.org/10.1109/isbi60581.2025.10980673
- 9.
Sundgaard JV, Juhl KA, Kofoed KF, Paulsen RR. Multi-planar whole heart segmentation of 3D CT images using 2D spatial propagation CNN. In: Medical Imaging 2020: Image Processing, 2020. 69. https://doi.org/10.1117/12.2548015
- 10.
Tian J, Chen B, Li Q, Liu R, Feng Y. An Efficient Spatial Modeling Conv-ViT using Mask Supervision for 3D Medical Image Segmentation. In: 2024 International Joint Conference on Neural Networks (IJCNN), 2024. 1–8. https://doi.org/10.1109/ijcnn60899.2024.10650648
- 11. Li H, Li J, Lin X, Qian X. Pancreas segmentation via spatial context based U-net and bidirectional LSTM. arXiv. 2019.
- 12. Hung ALY, Zheng H, Miao Q, Raman SS, Terzopoulos D, Sung K. CAT-Net: a cross-slice attention transformer model for prostate zonal segmentation in MRI. IEEE Trans Med Imaging. 2023;42(1):291–303. pmid:36194719
- 13. Yu Hung AL, Zheng H, Zhao K, Du X, Pang K, Miao Q, et al. CSAM: A 2.5D cross-slice attention module for anisotropic volumetric medical image segmentation. IEEE Winter Conf Appl Comput Vis. 2024;2024:5911–20. pmid:39193208
- 14.
Bunea AA, Popovici DM, Ionescu RT. SegMate: asymmetric attention-based lightweight architecture for efficient multi-organ segmentation. 2026. https://arxiv.org/abs/2602.23903
- 15.
Stanford AIMI Center. COCA: Coronary Calcium and Chest CT’s. Stanford AIMI. 2023. https://aimi.stanford.edu/datasets/coca-coronary-calcium-chest-ct Accessed 2026 July 15.
- 16.
Vaswani A, Shazeer N, Parmar N, Uszkoreit J, Jones L, Gomez AN, et al. Attention is all you need. In: Advances in Neural Information Processing Systems 30 (NIPS 2017), 2017. 5998–6008. https://proceedings.neurips.cc/paper/2017/hash/3f5ee243547dee91fbd053c1c4a845aa-Abstract.html
- 17.
He K, Zhang X, Ren S, Sun J. Deep Residual Learning for Image Recognition. In: 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), 2016. 770–8. https://doi.org/10.1109/cvpr.2016.90
- 18.
Loshchilov I, Hutter F. Decoupled weight decay regularization. In: 7th International Conference on Learning Representations (ICLR 2019); New Orleans, LA, 2019. https://openreview.net/forum?id=Bkg6RiCqY7
- 19.
Paszke A, Gross S, Massa F, Lerer A, Bradbury J, Chanan G, et al. PyTorch: An imperative style, high-performance deep learning library. In: Advances in Neural Information Processing Systems 32 (NeurIPS 2019), 2019. 8024–35.
- 20. Isensee F, Jaeger PF, Kohl SAA, Petersen J, Maier-Hein KH. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat Methods. 2021;18(2):203–11. pmid:33288961
- 21.
Perera S, Navard P, Yilmaz A. SegFormer3D: an Efficient Transformer for 3D Medical Image Segmentation. In: 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW), 2024. 4981–8. https://doi.org/10.1109/cvprw63382.2024.00503
- 22.
Sadegheih Y, Bozorgpour A, Kumari P, Azad R, Merhof D. LHU-Net: a lean hybrid U-Net for cost-efficient, high-performance volumetric segmentation. In: Gee JC, Alexander DC, Hong J, Iglesias JE, Sudre CH, Venkataraman A, et al., editors. Medical Image Computing and Computer Assisted Intervention – MICCAI 2025. Cham: Springer; 2026. pp. 326–36. https://doi.org/10.1007/978-3-032-05185-1_32
- 23.
Ronneberger O, Fischer P, Brox T. U-Net: convolutional networks for biomedical image segmentation. Lecture Notes in Computer Science. Springer International Publishing. 2015. p. 234–41. https://doi.org/10.1007/978-3-319-24574-4_28
- 24.
Xie E, Wang W, Yu Z, Anandkumar A, Alvarez JM, Luo P. SegFormer: simple and efficient design for semantic segmentation with transformers. In: Advances in Neural Information Processing Systems, 2021. 12077–90. https://proceedings.neurips.cc/paper/2021/hash/64f1f27bf1b4ec22924fd0acb550c235-Abstract.html
- 25.
Huang G, Liu Z, Van Der Maaten L, Weinberger KQ. Densely Connected Convolutional Networks. In: 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), 2017. 2261–9. https://doi.org/10.1109/cvpr.2017.243
- 26.
Tan M, Le Q. EfficientNet: rethinking model scaling for convolutional neural networks. In: Proceedings of the 36th International Conference on Machine Learning (ICML 2019), 2019. 6105–14. https://proceedings.mlr.press/v97/tan19a.html
- 27.
Rahman MM, Munir M, Marculescu R. EMCAD: Efficient Multi-Scale Convolutional Attention Decoding for Medical Image Segmentation. In: 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 2024. 11769–79. https://doi.org/10.1109/cvpr52733.2024.01118
- 28. Wang W, Xie E, Li X, Fan D-P, Song K, Liang D, et al. PVT v2: Improved baselines with pyramid vision transformer. Comp Visual Med. 2022;8(3):415–24.
- 29. Li P, Zhou R, He J, Zhao S, Tian Y. A global-frequency-domain network for medical image segmentation. Comput Biol Med. 2023;164:107290. pmid:37579584
- 30. Tang S, Ran H, Yang S, Wang Z, Li W, Li H, et al. A frequency selection network for medical image segmentation. Heliyon. 2024;10(16):e35698. pmid:39220902
- 31. Ruan J, Gao J, Xie M, Xiang S. Learning multi-axis representation in frequency domain for medical image segmentation. Mach Learn. 2025;114.

관련 뉴스