Diagnosing Ghost Bunches with the Upstream Extinction Monitor in the Mu2e Experiment
이 뉴스, 어떠셨어요?
한 번의 탭으로 반응을 남겨요 · 로그인 불필요
Abstract
The Mu2e experiment has a stringent requirement for extinction of the pulsed proton beam, referring to the elimination of particles between proton bunches to a relative level of 10$^-10$, which means a single out-of-time particle in the inter-pulse gaps for every 250 complete proton pulses.
As the construction of the Mu2e experiment nears completion, it is crucially important to make an early measurement of the beam extinction in its current condition.
Hence the upstream extinction monitor was constructed and operated to probe for problems in the proton pulse structure or a higher than expected incidence rate of out-of-time particles.
The analysis in this work comes from data taken in March 2026.
The long data run showed a significant presence of out-of-time particles from ghost bunches in the Delivery Ring approximately 388 ns after the centers of the main proton pulses.
These are hypothesized to be the result of a combination of a RF frequency mismatch, particle space charge, and machine impedance during the rebunching sequence in the Recycler Ring, which can lead to particles leaking into adjacent buckets, but further studies and simulations are needed to confirm this