Geometry Sets the Neutral MLIP-DFT Gap in Non-Covalent Binding, and Charged Systems Fail
Abstract
Pretrained universal machine-learning interatomic potentials (MLIPs) are widely expected to substitute for explicit quantum chemistry when screening molecular interactions.
On non-covalent binding we find that this expectation holds for neutral chemistry and fails for charged chemistry.
We audit the FAIRChem UMA OMol head, without task-specific fine-tuning, on 5,567 probe-target dimers from 18 benchmarks across nine fidelity arms, using RAPIDS (Rapid Atomistic Probe-target Interaction Discovery Scaffold), a training-free inference-time scaffold.
First, on neutral chemistry RAPIDS reaches a mean absolute error (MAE) of 1.37 kcal/mol, matching or beating every explicit DFT single-point fidelity (1.42-1.50 kcal/mol), so the remaining MLIP-DFT gap is geometric rather than a learned-surface error.
Second, charged systems form a qualitatively different regime: MAE jumps to 8.5-22.9 kcal/mol across three charged benchmarks; DFT single-point rescoring does not restore accuracy, geometry reoptimization restores it for ionic hydrogen bonds and ion-molecule dimers, and the failure persists across all three MLIP backbones.
Third, the residual failures are structured: signed biases cluster by chemistry family, and whether a fidelity fails catastrophically transfers across families more reliably than error magnitude, enabling cost-aware fidelity selection.
RAPIDS-Select, a closed-form rule on cheap precomputed features, uses about 37% less compute than a strong static DFT baseline at matched accuracy, and on a newly computed charged benchmark cuts the catastrophe rate from 68% to 5.7%.
On WetSenseBench, a wet-lab-grounded host-guest selectivity benchmark from eight sensing studies, RAPIDS without DFT follow-up recovers 82.9% pair-level agreement on the seven studies above its ~1 kcal/mol precision floor.